ROOF COVERING SYSTEMS

MALARKEY ROOFING PRODUCTS - Portland, OR USA

CLASS "A"


Comb. Deck
Slope: 1/2:12 (AC-1)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. Isocyanurate insulation board mechanically fastened.
    3. *1-Ply "#501", "#503", "#508", "#515", "#602", "#603", "#605 Panoply", mechanically fastened, fully adhered with ASTM-D312 roofing asphalt, "#1000 ESHAvent" self-adhesive base sheet.
    4. *1-, 2-, 3-Plies "#500", "#506" ply sheet, "#501" or "#503" base sheet, hot mopped. Coated with "Malarkey Asphalt", ASTM-D1227 asphalt emulsion at 4 gal./sq.

Comb. Deck
Slope: 1:12 (AC-2)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. 2 Plies of "#501", "#503" or "#515" base sheet (ASTM-D4601) mechanically attached.
    3. 1 Ply of "#160 APP", torched.
    4. 2 Gallons per 100 sq./ft. of "#726 Aluminum Coating" (per ASTM-D2824 Type III).

Comb. Deck
Slope: 1-1/2:12 (AC-3)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. 1 Ply of "#1000 ESHA Vent®" self adhesive base sheet, glued.
    3. 1 Ply of "#161 APP" cap sheet, torched.

Comb. Deck
Slope: 1:12 (AC-4)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. 1 Ply of #501, "#503" or #515.
    3. 1 Ply of #159 APP, torched base sheet.
    4. 1 Ply of #160 APP, torched base sheet.
    5. 2 Gallons of Aluminum Coating.

Comb. Deck
Slope: 1/2:12 (AC-5)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. *1-Ply "#501", "#503", "#515", "#602", "#603", "#605 Panoply" base sheet, hot mopped, mechanically fastened.
    3. *1-, 2-, 3-Plies of "#500", "#506" ply sheets, hot mopped.
    4. *1-Ply "#601 Premium" cap sheet, hot mopped.

Comb. Deck
Slope: Unlimited (AC-6)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. *"#230" Alaskan SBS Modified Fiberglass Shingles, installed per manufacturer's instructions.

Note: This system is ASTM-D3161 Wind Resistance rated up to 110 mph. In addition, it has been tested to UL-2218, and it has achieved a class 4 impact resistance rating under criteria established by the Texas Department of Insurance.

Comb. Deck
Slope: Unlimited (AC-7)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. "#240 Hurricane" SBS Modified Fiberglass Shingles, installed per manufacturer's instructions.

Note: This system is ASTM-D3161 Wind Resistance rated up to 110 mph. In addition, it has been tested to UL-2218, and it has achieved a class 4 impact resistance rating under criteria established by the Texas Department of Insurance.

Comb. Deck
Slope: 1/2:12 (AC-8)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. *Optional - 1-Ply "#501", "#503", "#602", "#603", "#605" base sheet, mechanically attached or fully adhered with "#705", ASTM-D3019 cold process adhesive, ASTM-D312 roofing asphalt, hot mopped, 1-ply "#1000 ESHAvent®" self-adhesive base sheet.
    3. *1-Ply "#602", "#603", "#605" or 2-Plies "#501" or "#503" base sheet, mechanically fastened or fully adhered with "#705", ASTM-D3019 cold process adhesive, ASTM-D312 roofing asphalt, hot mopped, 1-Ply "#1000 ESHAvent®" self-adhesive base sheet.
    4. *1-Ply "#601 Premium" cap sheet, fully adhered with ASTM-D3019 cold process adhesive, ASTM-D312 roofing asphalt, hot mopped.

Comb. Deck
Slope: 1/2:12 (AC-9)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. *1-, 2-, 3-Plies "#501", "#503", "#602", "#603", "#605 Panoply" base sheet, mechanically fastened, or fully adhered with ASTM-D312 roofing asphalt, hot mopped.
    3. *1-Ply "#917 Polyglass" cap sheet, torched down or fully adhered with "#705", ASTM-D3019 cold process adhesive, roofing asphalt, hot mopped.

Comb. Deck
Slope: 1/2:12 (AC-10)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. *1-, 2-, 3-Plies "#501", "#503", "#602", "#603", "#605 Panoply" base sheet, mechanically fastened, or fully adhered with ASTM-D312 roofing asphalt, hot mopped.
    3. *1-Ply "#919 Polyglass" cap sheet, torched down or fully adhered with cold process adhesive or roofing asphalt, hot mopped.
    4. Manufacturer specified water based emulsion coating meeting ASTM-D1227 specifications.

Comb. Deck
Slope: 1/2:12 (AC-11)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. *2-, 3-Plies "#501", "#503", "#602", "#603", "#605 Panoply" base sheet, fully adhered with ASTM-D312 roofing asphalt, hot mopped.
    3. *1-Ply "#601 Premium" cap sheet, fully adhered with ASTM-D312 roofing asphalt, hot mopped.

Comb. Deck
Slope: 1/2:12 (AC-12)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. *1-Ply "#501", "#503" fully adhered with ASTM-D312 roofing asphalt, hot mopped.
    3. *2-Plies "#603", fully adhered with ASTM-D312 roofing asphalt, hot mopped.
    4. Surfaced with ASTM-D1227 asphalt emulsion applied at a minimum coverage rate of 3 gal./sq.

Comb. Deck
Slope: 1/4:12 (AC-13)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. *3-, 4-Plies "#501", "#503", "#602", "#603", "#605 Panoply" base sheet, fully adhered with "#705" Adhesive, or ASTM-D3019 cold process adhesive applied at a coverage rate of 2 gal./sq. each ply.
    3. *Coated with "#705 Adhesive", or ASTM-D3019 cold process adhesive, at 2 gal./sq. and embedded with 3M Brand No. 11 roofing granules at a minimum coverage rate of 60 lbs./sq.
    OR

    4. *Coated with "#705 Adhesive", or ASTM-D3019 cold process adhesive, at 4 gal./sq. and embedded with roofing gravel ballast at a minimum coverage rate of 400 lbs./sq.

Comb. Deck
Slope: 2:12 (AC-14)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. *1-Ply "#501", "#503", "#515" base sheet or inverted "#502" cap sheet, mechanically fastened (optional when minimum 1/2" insulation board is applied).
    3. *2-, 3-Plies "#501" or "#503" base sheet, "#500", "#506" ply sheet, fully adhered with ASTM-D312 roofing asphalt, hot mopped.
    4. *1-Ply "#350", "#502" cap sheet, fully adhered with ASTM-D312 roofing asphalt, hot mopped.

Comb. Deck
Slope: 1/2:12 (AC-15)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. *1-Ply "#501", "#503", "#602", "#603", "#605 Panoply" glass fibered base sheet, mechanically fastened.
    3. *1-Ply "#919 Polyglass" cap sheet, fully adhered with ASTM-D312 Type III roofing asphalt, hot mopped, or "#705" or ASTM-D3019 cold process adhesive.
    4. Surfaced with "Malarkey" aluminum roof coating applied at a minimum coverage rate of 1-1/2 gal./sq.

Comb. Deck
Slope: Unlimited (AC-16)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. *3-, 4-Plies "#501", "#503", "#515", "#602", "#603", "#605 Panoply" base sheet, fully adhered each ply with ASTM-D312 roofing asphalt or "#705" adhesive or ASTM-D3019 cold process adhesive.
    3. Flood coated with roofing asphalt or adhesive and embedded with nominal 3/8" pea gravel at a minimum coverage rate of 150 lbs./sq.
    4. Optional - "Heatshield" primer and rock bonder applied at a coverage rate of 1 gal./sq.
    5. Surfaced with "Heatshield" cementitious coating per manufacturers' instructions.

Comb. Deck
Slope: 1:12 (AC-17)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. *1-Ply "#501", "#503", "#515", "#602", "#603", "#605 Panoply" base sheet, mechanically fastened, or fully adhered with "#705" or ASTM-D3019 cold process adhesive or ASTM-D312 roofing asphalt, hot mopped, or 1-Ply "#1000 ESHAvent®" self-adhesive base sheet.
    3. Optional - 1-Ply "#500", "#506" ply sheet or "#501", "#503", "#602", "#603", "#605 Panoply" base sheet, fully adhered with "#705" or ASTM-D3019 cold process adhesive or ASTM-D312 roofing asphalt, hot mopped.
    4. *1-Ply "#917 Polyglass" cap sheet, fully adhered with "#705" or ASTM-D3019 cold process adhesive or ASTM-D312 roofing asphalt, hot mopped.

Comb. Deck
Slope: 2:12 (AC-18)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. *"#1000 ESHAvent®" thermally adhered roofing membrane.
    3. *1-Ply Item "#500" ply sheet, hot mopped with ASTM-D312 asphalt.
    4. *1-Ply of "#601", "#350", "#502", "#917", "#919" cap sheet.

Comb. Deck
Slope: 3:12 (AC-19)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. * 3-, 4-Plies "#500", "#503", "#506" ply sheet or "#501", "#515", "#602", "#603", "#605 Panoply", mechanically fastened or fully adhered first ply, subsequent plies fully adhered with cold process adhesives or ASTM-D312 roofing asphalt.
    3. Roofing gravel ballast applied at a minimum 400 lbs./sq. into flood coat of cold process adhesive or roofing asphalt.

Comb. Deck
Slope: N/A (AC-20)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. *"#210 PRO-25" SBS Modified Fiberglass Shingles, installed per manufacturer's instructions.

Note: This system is ASTM-D3161 Wind Resistance rated up to 60 mph.

Comb. Deck
Slope: Unlimited (AC-21)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. Approved underlayment installed per manufacturer's instruction.
    3. #272 Legacy SBS Modified Laminated Shingles, mechanically attached.

Note: This system has been tested to UL-2218, and it has achieved a class 4 impact resistance rating under criteria established by the Texas Department of Insurance. This system is ASTM-D3161 Wind Resistance rated up to 110 mph.

Comb. Deck
Slope: Unlimited (AC-22)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. #270 Northwest XL Shingles or #271 Highlander CS Laminated Shingles, mechanically attached.

Note: This system with #271 Highlander CS Laminated Shingles are is ASTM-D3161 Wind Resistance rated up to 80 mph. The system with #270 Northwest XL Laminated Shingles are ASTM-D3161 Wind Resistance rated up to 110 mph.

Comb. Deck
Slope: Unlimited (AC-23)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. *"#250 Monterey" SBS modified fiber glass shingles, installed per manufacturer's instructions.

Comb. Deck
Slope: 1:12 (AC-24)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. *1- or more Plies "#501", "#515", "#602", "#603", "#605 Panoply" base sheet mechanically attached or fully adhered with ASTM-D312 roofing asphalt, hot mopped, or 1-Ply of "#1000 ESHAvent®", self-adhesive base sheet.
    3. *1- or more Plies "#500", "#506" ply sheet, "#501", "#515", "#602", "#603", "#605 Panoply" fully adhered with ASTM-D312 roofing asphalt, hot mopped. Optional when insulation is used.
    4. *1-Ply "#650 Panoply", "#625 Paragon" SBS cap sheet, fully adhered with ASTM-D312 roofing asphalt, hot mopped.

Comb. Deck
Slope: Unlimited (AC-25)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. *1-Ply "#501", "#503", "#602", "#603", "#605 Panoply" base sheet, mechanically fastened or fully adhered with ASTM-D312 roofing asphalt, hot mopped.
    3. *1- or more Plies "#500", "#506" ply sheet or "#501", "#503", "#602", "#603", "#605 Panoply" base sheet, fully adhered with ASTM-D312 roofing asphalt, hot mopped. Optional when insulation is used.
    4. *1-Ply "#1020 ESHAlum®", fully adhered with ASTM-D312 roofing asphalt, hot mopped.

Comb. Deck
Slope: 1-1/2:12 (AC-26)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. Two plies of #501, "#503" or #515 base sheet ASTM-D4601, mechanically fastened.
    3. One ply of #161 APP cap sheet, torched.

Comb. Deck
Slope: 1:12 (AC-27)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. One ply of #1000 ESHA Vent self adhesive base sheet, glued.
    3. One ply of #159 APP base sheet, torched.
    4. One ply of #160 APP ply sheet, torched.
    5. Two gallons per 100 sq.ft. of #726 Aluminum Coating per ASTM-D2824 Type III.

Comb. Deck
Slope: 1:12 (AC-28)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. Two plies of #501, "#503" or #515 base sheet ASTM-D4601 mechanically attached.
    3. One ply of #159 APP base sheet, torched.
    4. Two gallons per 100 sq.ft. of #726 Aluminum Coating per ASTM-D2824 Type III.

Comb. Deck
Slope: 1-1/2:12 (AC-29)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. One ply of #501, "#503" or #515 base sheet ASTM-D4601 mechanically attached.
    3. One ply of #159 APP base sheet, torched.
    4. One ply of #161 APP cap sheet, torched.

Comb. Deck
Slope: 2:12 (AC-30)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. Minimum 1/4" thick Dens Deck, mechanically fastened or applied in hot asphalt.
    3. *"Sealoflex Pink", applied at a coverage rate of 2.5 gal/100 sq.ft.
    4. *"Sealoflex Fabric", imbedded per manufacturer's instruction.
    5. *"Sealoflex Finish Coat", applied at a coverage rate of 1.43 gal/100 sq.ft.

Comb. Deck
Slope: 2:12 (AC-31)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. 1-Ply "#501", "#503", "#515" base sheet, or inverted "#502" cap sheet, mechanically fastened.
    3. 1 or more Plies, "#501" or "#503" base sheet, "#500", "#506" ply sheet, fully adhered with ASTM-D312 roofing asphalt, hot mopped.
    4. 1-Ply "#350", "#502" cap sheet, fully adhered with ASTM-D312 roofing asphalt, hot mopped.

Comb. Deck
Slope: 1:12 (AC-32)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. 1-Ply #1000 ESHA Vent self adhesive base sheet, glued.
    3. 1-Ply #159 APP base sheet, torched.
    4. 1-Ply #161 APP cap sheet.

Comb. Deck
Slope: 1:12 (AC-33)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. 1-Ply of "#501" UDL underlayment or inverted "#502" cap sheet, mechanically fastened.
    3. 1-Ply of "#501" SBS base sheet adhered with "#727" modified bituminous adhesive, and coated with "#727" modified bituminous adhesive.
    4. "#750" non-fibered adhesive applied at 9 gallons/100 sq.ft.
    5. 2 gallons per 100 sq.ft. of "#726" aluminum coating per ASTM-D2824 Type III.

Non-Comb. Deck
Slope: 1:12 (AN-1)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. 1-Ply "#1000 ESHAvent®" thermally adhered.
    3. 3-Plies "#500 Fiberglass" ply sheet, hot mopped with ASTM-D312 roofing asphalt.
    4. Roofing gravel ballast applied at a minimum 400 lbs./sq. into flood coat of cold adhesive or ASTM-D312 roofing asphalt.

Non-Comb. Deck
Slope: 2:12 (AN-2)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. *Optional - 1-Ply "#501", "#503", "#515", "#602", "#603", "#605 Panoply" base sheet.
    3. *1-Ply "#602", "#603", "#605 Panoply", or 2-Plies "#501" or "#503" base sheet, fully adhered with ASTM-D312 roofing asphalt, hot mopped.
    4. 1-Ply "#601 Premium" cap sheet, fully adhered with ASTM-D312 roofing asphalt, hot mopped, or "#705" or ASTM-D3019 cold process adhesive at 2 gal./sq.

Non-Comb. Deck
Slope: 1/2:12 (AN-3)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. *Optional - 1-Ply "#1000 ESHAvent®" self-adhesive base sheet.
    3. *3-, 4-Plies "#501", "#503", "#602", "#603", "#605 Panoply" base sheet, fully adhered with "#705" Adhesive or hot mopped with ASTM-D312 roofing asphalt each ply.
    4. Coated with ASTM-D1227 roofing asphalt emulsion at a minimum of 3 gal./sq.
    5. Optional Surfacing - "Malarkey", ASTM-D2824 aluminum roof coating applied at a minimum coverage rate of 1-1/2 gal./sq.

Non-Comb. Deck
Slope: 1/2:12 (AN-4)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. *1-, 2-, 3-Plies "#501", "#503", "#602", "#603", "#605 Panoply" base sheet, fully adhered with ASTM-D312 roofing asphalt, hot mopped, or 1-Ply "#1000 ESHAvent®" self-adhesive base sheet.
    3. *1-Ply "#601 Premium" cap sheet, fully adhered with ASTM-D312 roofing asphalt, hot mopped.

Non-Comb. Deck
Slope: 1/2:12 (AN-5)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. *3-, 4-Plies "#501", "#503", "#602", "#603", "#605 Panoply" glass fibered base sheet, mechanically fasten first ply, fully adhere subsequent plies with either:
    a. Type III roofing asphalt OR
    b. Approved cold process adhesive(s).

    3. Surfaced with roofing gravel ballast at a minimum coverage rate of 400 lbs./sq. embedded into a flood coat of one of the adhesive systems noted above.

Non-Comb. Deck
Slope: 1/2:12 (AN-6)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. Optional - 1-Ply "#501", "#503", "#602", "#603", "#605 Panoply" base sheet or "#1000 ESHAvent®" self-adhesive base sheet.
    3. *1-Ply "#602", "#603", "#605 Panoply" or 2-Plies "#501" or "#503" glass fiber base sheet, mechanically fastened or fully adhered with ASTM-D312 asphalt, hot mopped.
    4. *1-Ply "#601 Premium" cap sheet, fully adhered with approved cold process adhesive or fully adhered with ASTM-D312 asphalt, hot mopped.

Non-Comb. Deck
Slope: 2:12 (AN-7)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. Optional min. 1/4" thick Dens Deck, mechanically fastened or applied in hot asphalt.
    3. *"Sealoflex Pink", applied at a coverage rate of 2.5 gal/100 sq.ft.
    4. *"Sealoflex Fabric", imbedded per manufacturer's instruction.
    5. *"Sealoflex Finish Coat", applied at a coverage rate of 1.43 gal/100 sq.ft.

Non-Comb. Deck
Slope: 2:12 (AN-8)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. Min. 1/4" thick Dens Deck, mechanically fastened or applied in hot asphalt.
    3. *"Sealoflex Pink", applied at a coverage rate of 2.5 gal/100 sq.ft.
    4. *"Sealoflex Fabric", imbedded per manufacturer's instruction.
    5. *"Sealoflex Finish Coat", applied at a coverage rate of 1.43 gal/100 sq.ft.

Non-Comb. Deck
Slope: 1/2:12 (AN-9)

    1. Optional Insulations: Manufacturer specified, certified insulations..
    2. *1-Ply "#501", "#503", "#602", "#603", "#605 Panoply" glass fiber base sheet, mechanically fastened, or fully adhered with cold process adhesive, or "#1004 ESHAvent®" self-adhesive base sheet.
    3. *2-Plies "#501", "#503", "#602", "#603", "#605 Panoply" glass fiber base sheet fully adhered with cold process adhesive at 1-1/2 gal./sq. each ply, or fully adhered with ASTM-D312 asphalt, hot mopped.
    4. Manufacturer specified non-fibered emulsion coating at 3 gal./sq.
    5. 3M Brand Roofing Granules embedded at 50 lbs./sq.

Non-Comb. Deck
Slope: 3:12 (AN-10)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. *Optional Base Sheet - 1-Ply "#501", "#503", "#508", "#515", "#602", "#603", "#605 Panoply" fully adhered with ASTM-D312 roofing asphalt, hot mopped, or 1-Ply "#1000 ESHAvent®" self-adhesive base sheet.
    3. *2-, 3-, 4-Plies "#500", "#506" ply sheet or "#501", "#503", "#602", "#603", "#605 Panoply" base sheet fully adhered with ASTM-D312 roofing asphalt, hot mopped.
    4. Flood coat with ASTM-D312 roofing asphalt, gravel ballast at 400 lbs./sq.

Non-Comb. Deck
Slope: 3:12 (AN-11)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. *1-, 2-, 3-Plies "#501", "#503", "#602", "#603", "#605 Panoply" base sheet, fully adhered with ASTM-D312 roofing asphalt, hot mopped.
    3. *1-Ply "#917", "#919 Polyglass" cap sheet, fully adhered with ASTM-D312 roofing asphalt, hot mopped.
    4. Flood coat with ASTM-D312 roofing asphalt.
    5. Pea gravel ballast at 400 lbs./sq.

Non-Comb. Deck
Slope: 1/2:12 (AN-12)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. Malarkey #502 Base Sheet, inverted, mechanically attached.
    3. Malarkey #919 Ply Sheet, hot mopped with ASTM-D312 asphalt.
    4. Malarkey #917 Cap Sheet, hot mopped with ASTM-D312 asphalt.

Non-Comb. Deck
Slope: 2:12 (AN-13)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. Optional min 1/4" thick Dens Deck, mechanically fastened or applied in hot asphalt.
    3. *"Sealoflex Pink", applied at a coverage rate of 2.5 gal/100 sq.ft.
    4. *"Sealoflex Fabric", imbedded per manufacturer's instruction.
    5. *"Sealoflex Finish Coat", applied at a coverage rate of 1.43 gal/100 sq.ft.

Non-Comb. Deck
Slope: 2:12 (AN-14)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. *"Sealoflex Pink", applied at a coverage rate of 2.5 gal/100 sq.ft.
    3. *"Sealoflex Fabric", imbedded per manufacturer's instruction.
    4. *"Sealoflex Finish Coat", applied at a coverage rate of 1.43 gal/100 sq.ft.

Non-Comb. Deck
Slope 5:12 (Unlimited) (AN-15)

    1. Base Layer: 2" thick "nail base" insulation mechanically attached to a steel substrate (deck).
    2. Intermediate Layer: One layer of Type 15 or Type 30 asphalt saturated felt.
    3. Cap Layer: One layer of "Alaskan" shingles, installed per manufacturer's installation instructions.

CLASS "B"


Comb. Deck
Slope: 1/2:12 (BC-1)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. *1-Ply "#919" smooth cap sheet, torched down.
    3. *Coated with "Rhino-Hide Ti-Cote" at 4 gal./sq.

Comb. Deck
Slope: 1:12 (BC-2)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. 1 Ply of #501, "#503" or #515 Base Sheet, mechanically attached.
    3. 1 Ply of #160 APP, torched.
    4. 2 gallon per 100 sq.ft. of #726 Aluminum Coating per ASTM-D2824 Type III.

Comb. Deck
Slope: 1/2:12 (BC-3)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. *2-Plies "#500", "#506" ply sheet, or "#501", "#503", "#602", "#603", "#605 Panoply" base sheet, hot mopped with ASTM-D312 roofing asphalt.
    3. Coated with ASTM-D1227 emulsified asphalt at 3 gal./sq.

Comb. Deck
Slope: 1/2:12 (BC-4)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. *1-Ply "#601 Premium" cap sheet, fully adhered with ASTM-D312 roofing asphalt, hot mopped.

Comb. Deck
Slope: 1/2:12 (BC-5)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. *2- or more Plies "#501", "#503", "#602", "#603", "#605 Panoply" glass fiber base sheet, fully adhered with cold process adhesive at 1-1/2 gal./sq. each ply.
    3. Coated with ASTM-D1227 asphalt emulsion at 3 gal./sq.
    4. 3M Brand Roofing Granules embedded at 50 lbs./sq.

Comb. Deck
Slope: 2:12 (BC-6)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. *Optional - 1-Ply "#501", "#503", "#602", "#603", "#605 Panoply" base sheet.
    3. *1-Ply "#602", "#603", "#605 Panoply" or 2-Plies "#501" or "#503" base sheet, fully adhered with ASTM-D312 roofing asphalt, hot mopped.
    4. *1-Ply "#601 Premium" cap sheet, fully adhered with ASTM-D312 roofing asphalt, hot mopped.

Comb. Deck
Slope: 1/2:12 (BC-7)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. *1- or more Plies, "#501", "#503", "#602", "#603", "#605 Panoply" base sheet, mechanically fastened or fully adhered with "#705" or ASTM-D3019 cold process adhesive, or ASTM-D312 roofing asphalt, hot mopped.
    3. *1-Ply "#601 Premium" cap sheet, fully adhered with ASTM-D3019 cold process adhesive, or ASTM-D312 roofing asphalt, hot mopped.

Comb. Deck
Slope: 1-1/2:12 (BC-8)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. One ply of #501, "#503" or #515 base sheet ASTM-D601 mechanically attached.
    3. One ply of #161 APP cap sheet, torched.

Comb. Deck
Slope: 1:12 (BC-9)

    1. Optional Insulations: Manufacturer specified, certified insulations.
    2. One ply of #1000 ESHA Vent self adhesive base sheet glued.
    3. One ply of #160 APP ply sheet, torched.
    4. Two gallons per 100 sq.ft. of #726 Aluminum Coating per ASTM-D2824 Type III.

+Evaluated to the following...

For additional information, please call or write:
Malarkey Roofing Products P.O. Box 17217 Portland, OR 97217
(503) 283-1191 or (800) 545-1191 Facsimile (503) 289-7644

Malarkey Home

 © 2008 Malarkey Roofing Products, All Rights Reserved



Browse our other web pages...

Malarkey Home

Shingle Colors &
Homeowner Information

Commercial Roofing, plus
Contractor & Technical Services

Class 4 Impact Rating 
Scotchgard Algae Resistant
Roofing System from 3M

Technical Data Sheets
Product Data Guide
MSDS Sheets

Click here to request
Product Samples

Click here to contact the
Malarkey web administrator